Medical Device Cybersecurity Checklist (TARA-based)
A step-by-step guide for healthcare IT, clinical engineering, and device manufacturers to secure connected medical systems across the full product lifecycle. Built on PTRG's threat-analysis-and-risk-assessment (TARA) methodology and aligned to FDA Premarket Cybersecurity Guidance, the HIPAA Security Rule, ISO 14971, IEC 62304, and AAMI TIR57.
DNSystems LLC · PTRG · dnsystemsllc.com
1. Scope & Asset Inventory
- List every connected device, model, and firmware/software version in scope.
- Map each device's data flows: on-device, LAN, cloud, mobile app, and update channel.
- Identify the protected health information (PHI) each device stores or transmits.
- Record trust boundaries: who/what talks to the device and over which interface.
- Note remote-access and telemetry paths (vendor support, OTA, cloud dashboards).
2. Threat Identification
- Enumerate threat scenarios against the device, its APIs, cloud, and update mechanism.
- Classify each with STRIDE.
- Include patient-safety threats (incorrect treatment, disabled therapy, false readings).
- Include privacy threats (PHI exposure, unauthorized access, data leakage).
- Include availability threats (device unavailable when clinically needed).
3. Risk Assessment
- Rate feasibility of each threat (attacker access, skill, tooling, known exploits).
- Rate impact across safety, privacy, operational, and financial dimensions.
- Calculate risk = feasibility × impact; prioritize the highest first.
- Cross-reference ISO 14971 harm/risk analysis so cyber risk feeds clinical risk.
4. Controls & Risk Treatment
- Authentication: strong, unique credentials; OAuth 2.0 / token auth on every API.
- Authorization: least-privilege access; no shared or default accounts.
- Transport security: TLS 1.2+ for all device-to-app and device-to-cloud traffic.
- Data-at-rest encryption for PHI on device and in the cloud.
- API hardening: rate limiting, input validation, anomaly alerting, request throttling.
- Secure boot / signed firmware and a verified, authenticated update mechanism.
- Logging, auditing, and monitoring of access and API usage.
- Network segmentation for clinical/OT networks; isolate unmanaged devices.
5. Verification & Evidence
- Penetration test the device, its APIs, cloud, and mobile app — with proof of exploitation.
- Produce a risk register mapping each threat to its control and residual risk.
- Capture documented test results and remediation retest evidence.
- Assemble compliance-ready evidence for FDA submissions and HIPAA audits.
6. Lifecycle & Monitoring
- Re-run the assessment at every software update or major configuration change.
- Maintain a coordinated vulnerability-disclosure / PSIRT process.
- Monitor components against new CVEs (SBOM + VEX) and re-triage exploitability.
- Keep the risk register living — update as threats and the deployment evolve.
Regulatory Alignment
- FDA Premarket Cybersecurity Guidance — design-phase risk management + submission evidence.
- HIPAA Security Rule — safeguarding PHI (administrative, physical, technical controls).
- ISO 14971 — medical device risk management.
- IEC 62304 — medical device software lifecycle processes.
- AAMI TIR57 — medical device cybersecurity risk management principles.
How PTRG delivers this: we author the TARA with an AI co-pilot, prove the risks with live penetration testing, map every finding to the frameworks above, and ship a signed, sealed deliverable (PDF, DOCX, slides, CSV) plus an interactive DeepGrid coverage map. One report bundle. No seat license.
Start free →